加载中,请稍候...
浏览历史

 


基于模块的IO安全控制

关键词: IXXAT Safe T100,


简介:IXXAT Safe T100for the quick and simple module-based implementation of safe IOs Product status Product announcement Availability December 2013 The IXXAT Safe T100 offers device manufacturers an easy way to control safe I/O signals using a safe field bus protocol. The module meets the SIL3 safety requirement level as defined by IEC 61508 and Performance Level PLe / Categ...
品 牌
产 地
型 号 PXF2027
折 扣

 

IXXAT Safe T100

for the quick and simple module-based implementation of safe IOs

Product status Product announcement
Availability December 2013

The IXXAT Safe T100 offers device manufacturers an easy way to control safe I/O signals using a safe field bus protocol. The module meets the SIL3 safety requirement level as defined by IEC 61508 and Performance Level PLe / Category 4 in IEC 13849-1. <a href='http://51lm.cn/t/10029.html' target='_blank'><font size='+1' color='#0000FF'><strong>IXXAT</strong></font></a> Safe T100 - for the quick and simple module-based implementation of safe IOs

It is used in customer devices together with a communication module of the ANYBUS CompactCom series , which is used to implement the unsafe bus connection. Safety communications use the black channel principle through the ANYBUS CompactCom communication module. For PROFIsafe, for example, the communication module carries out the tasks of a PROFINET I/O device. The IXXAT Safe T100/PS implements the PROFIsafe layer and the safe control of three dual-channel inputs, as well as one dual-channel output. 
The module's very compact dimension and flexible Safety I/O routing make it perfect for integration into customer-specific device solutions. 

The IXXAT Safe T100 is currently available for PROFIsafe. Support for additional safety protocols (CIP Safety and FSoE) is in progress. 

Black channel principle

Black channel principle


Simple certification 

For device certification, a comprehensive safety manual is provided. This describes all needed integration and verification steps to achieve the TÜV certification of IXXAT Safe T100-based end products with greatly reduced effort. Especially the clear separation of safety-relevant functions from the unsafe functions of the end device by the precertified IXXAT Safe T100 plug board is a great help in this situation.

 

Technical Data
Supported standards PROFIsafe (further versions for CIP Safety, FSoE and openSAFETY are planned)
Digital inputs 3 x dual channel, configurable with  
filter and monitor functions
Digital outputs 1 x dual channel, configurable
Safety Conformance Level SIL 3, PL e category 4
Power supply 24 V DC (SELV/PELV), 3.3 V DC
Environment temperature -40 °C to +85 °C
Dimensions 70 x 40 x 15 mm
Development kit

To evaluate the IXXAT Safe T100, a corresponding development kit is available as a reference implementation. It consists of a base board with a PROFINET I/O ANYBUS CompactCom communication module and a host CPU, along with an IXXAT Safe T100/PS with Safety I/O leads brought out. 
The configuration of the Safety I/Os uses PROFINET/PROFIsafe and is supported by a special configuration tool, which can be integrated seamlessly into the Siemens Step7 toolchain, for example. 

Order number
1.01.0300.00001 IXXAT Safe T100/PS
参数资料: 基于模块的IO安全控制IXXAT Safe T100,
该文章系原厂商文章翻译,不通之处请参考原文
  价格列表: 基于模块的IO安全控制IXXAT Safe T100,
葩星订货号 订货号 产品名称 报价 品牌  
  相关产品: 基于模块的IO安全控制IXXAT Safe T100,
  咨询历史: