简介:FIP Slave - CC Link Slave The Anybus X-gateway copies I/O-data in both directions thus enabling data ex改变 between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows.The FIPIO interface i...
The anybus X-gateway copies I/O-data in both directions thus enabling data ex改变 between the two networks. Default I/O configuration is 20 bytes Input and 20 bytes Output. Changing default settings is very simple and is carried out using the RS232 configuration port and a standard terminal interface on a PC, such as Hyper Terminal for Windows.
The FIPIO interface is based an embedded AnyBus-S module providing industrial performance and quality. FIPIO station address can be selected via switches on the end side of the module. A transformer 连接ion on the module provides a isolated fieldbus interface.
The CC-Link interface is a slave module for the CC-Link fieldbus system. It contains all the functionality needed to turn an application into a complete CC-Link remote device and it is configured to use the generic PLC profile. The CC-Link interface module is certified by the CLPA organisation and has proven conformance and interoperability with leading PLC´s, HMI´s etc
KEY FEATURES
Supports both FIP and WorldFIP standards
FIPIO profile FEDP (Extended Device Profile), class 0
Transformer isolated FIP interface
Uses up to 4 occupied stations on CC-Link - configurable size
Uses the CC-Link PLC profile for data ex改变
Support for CC-Link version 2.0 with extended data
TECHNICAL SPECIFICATIONS
Size:
126 mm x 110 mm x 42 mm
Power Supply:
24 VDC (±10%)
温度:
0-65°C
Current Consump:
max 300 mA
I/O Input:
Default 20 bytes, max 64 bytes (max 128 I/O-points and 16 words on CC-Link)
I/O Output:
Default 20 bytes, max 64 bytes (max 128 I/O-points and 16 words on CC-Link)
Mech Rating:
IP20/Nema1
Config Method:
Windows Hyper Terminal
UL certification:
E203225, Listed 67AM, UL-1604 Class 1, Div 2, GP A, B, C, D, Temp Code T4
ATEX certification:
ATEX 135419, II 3 G, EEx nL IIC T4, DEMKO 03
Power supply 连接or:
2-pole 5.08 mm Phoenix pluggable screw 连接or
FIPIO baudrate:
1 Mbit/s
FIPIO address:
Node address 0-99
FIPIO 连接or:
D-sub 9-pin male
CC-Link baudrate:
156kbps to 10Mbps
CC-Link address:
Station 1-64
CC-Link 连接or:
5-pole 5.08 mm Phoenix pluggable screw 连接or
CC-Link config.:
Configured by CC Link Master via CSP Config file (provided by HMS)