Fluke VoltAlert™ 1AC

1LAC-A试电笔

Easy-To-Use Voltage Detector

VoltAlert™ ac voltage tester from Fluke are easy to use-just touch the tip to a terminal strip, outlet, or cord. When the tip glows red, you know there's voltage in the line. Electricians, maintenance, service, safety personnel, and homeowners can quickly test for energized circuits and defective grounds on the factory floor, in the shop, or at home.

 
 
 
 
 
 80AK-A

 

  • Fits in a shirt pocket for convenience
  • All outer surfaces are non-conductive for safety
  • Detects voltage without metallic contact
  • Manufactured, printed and packaged in the US
  • Quickly locates the hot, neutral and ground terminals in any receptacle

 

 

 

 

 

 

Specifications
Voltage
   1AC-A (90 - 600 Volts AC)
   1AC-P (200 - 600 Volts AC)
   1AC-A (110 - 1000 Volts AC) Australia only
   1AC-P2 (200 - 600 Volts AC) NZ only

 

Environmental Specifications
Operating Temperature
   -10°C to 50 °C (14°F to 122°F)
Humidity (Without Condensation)
   0 °C to 30 °C, 95% (32°F to 86°F)
   30 °C to 40 °C, 75% (86°F to 104°F)
   40 °C tp 50 °C, 45% (104°F to 122°F)
Operating Altitude
   3000 m (9750 ft max)
Enclosure
   IEC 529, IP54

 

Safety Specifications
Safety Rating
   CAT III-600 V
   ANSI/ISA-S82.01-94
   IEC 1010-1, 1990
   IEC 1010-2-031

 

Mechanical & General Specifications
Size
   146mm L x 19 mm D (5.75" L x 0.75" D)
Weight
   41 g with batteries (1.45 oz)
Outer surface
   Probe is composed of injection molded high-impact, non-flammable PVC and ABS

 

 

Specifications
Voltage
   1AC-A (90 - 600 Volts AC)
   1AC-P (200 - 600 Volts AC)
   1AC-A (110 - 1000 Volts AC) Australia only
   1AC-P2 (200 - 600 Volts AC) NZ only

 

Environmental Specifications
Operating Temperature
   -10°C to 50 °C (14°F to 122°F)
Humidity (Without Condensation)
   0 °C to 30 °C, 95% (32°F to 86°F)
   30 °C to 40 °C, 75% (86°F to 104°F)
   40 °C tp 50 °C, 45% (104°F to 122°F)
Operating Altitude
   3000 m (9750 ft max)
Enclosure
   IEC 529, IP54

 

Safety Specifications
Safety Rating
   CAT III-600 V
   ANSI/ISA-S82.01-94
   IEC 1010-1, 1990
   IEC 1010-2-031

 

Mechanical & General Specifications
Size
   146mm L x 19 mm D (5.75" L x 0.75" D)
Weight
   41 g with batteries (1.45 oz)
Outer surface
   Probe is composed of injection molded high-impact, non-flammable PVC and ABS