The M-0.5 LVDT position sensor is ideal for high resolution measurements, up to 0.1 microns.
Being an AC LVDT it needs a signal conditioner to operate, such as LVDT Signal Conditioner model EL-10 or LVDT Signal Conditioner model EL-15, or LVDT Control Box CB-100 Series, or USB-10 Unit, manufactured by Singer Instruments & Control.
Different versions of this LVDT can be manufactured by request.
Specifications
|
|
|
Input voltage. . . . . . . . . .
|
3V rms (nominal)
|
|
Frequency range . . . . . .
|
50 to 10000 Hz range @ 5kHz
|
|
Linearity deviation error
|
(nominal)
|
|
0.15% F. R.
|
|
Operating temperature
|
-20oC to + 70oC
|
|
range. . . . . . . . . . . . . . . .
|
|
Shock Survival . . . . . . .
|
500g for 11 msec
|
|
Vibration tolerance. . . . .
|
20 g up to 500 Hz
|
|
Lead wires. . . . . . . . . . . .
|
6 wires, 300 mm long
|
|
Weight. . . . . . . . . . . . . . .
|
6 grams
|
|
Notes
|
|
|
|
|
How to order
|
|
|
|
|
LVDT installations require a connecting rod between the LVDT core
|
Ordering example:
|
|
|
|
|
and the object whose motion is being measured. This connecting rod
|
Model number: M – 0.5 (supplied with core)
|
must be made of non-magnetic stainless steel (for example AISI 304)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Linear Range
|
Sensitivity
|
|
Resistance
|
|
|
Impedance
|
|
|
TYPE
|
(tested at 5kHz)
|
|
|
|
(tested at 5kHz)
|
|
|
|
|
|
|
|
|
|
mm
|
|
V/mm/Vex
|
|
Ω
|
|
|
Ω
|
|
|
|
|
|
|
|
|
|
|
|
|
Prim.
|
|
Sec.
|
|
Prim.
|
|
Sec.
|
|
|
|
|
|
|
|
|
|
|
M-0.5
|
±0.5
|
|
0.25
|
|
190
|
|
190
|
|
630
|
|
500
|