IWATSU PHV_PHVS1000-R0
简介:High-voltage Probes HV-P60/HV-P30High-voltage Probes Model Bandwidth (MHz) Attenuation ratio 1: x Withstand voltage (duty 10%) Withstand voltage (duty 50%) DC Length (m) Remarks PHV1000-RO 400 100 6kV (500ms cycle) 3.5kV (100ms cycle) 1kV 2 CAT 1 PHVS1000-RO 400 ...
Brand
Made In
Modle PXF2321
Disctount
PassionTech Ord OrderNum Product Name Price RMB Brand  
PXO_0534HV-P30HV-P30岩崎示波器高压探头380~42030900
该文章系原厂商文章翻译,不通之处请参考原文

 

High-voltage Probes HV-P60/HV-P30

High-voltage Probes

Model Bandwidth
(MHz)
Attenuation
ratio 1: x
Withstand voltage
(duty 10%)
Withstand voltage
(duty 50%)
DC Length (m) Remarks
PHV1000-RO 400 100 6kV (500ms cycle) 3.5kV (100ms cycle) 1kV 2 CAT 1
PHVS1000-RO 400 1000 6kV (500ms cycle) 3.5kV (100ms cycle) 1kV 2 CAT 1
PHV641-LRO 380 100 4kV (200ms cycle) 3.5kV (60ms cycle) 3kV (+AC peak) 1.2 AC rms 2kV
PHV661-LRO 380 100 6kV (200ms cycle) 5kV (60ms cycle) 4kV (+AC peak) 1.2 AC rms 2.8kV
PHV4002-3/0,6RO 100 1000 40kV (100ms cycle) 30kV (30ms cycle) 20kV (+AC peak) 3 AC rms 14kV

PHV1000-RO

PHV6xx-LRO

HV-P60

 HV-P60

High-voltage waveforms of up to DC 60 kV, pulse 80 kV measured by oscilloscope

 

Wide bandwidth, DC to 50 MHz

 

Maintenance-free, due to use of silicon rubber - guarantees stable withstand voltage

Specifications
Maximum input voltage DC 60 kV or AC peak*
Single-shot pulse of 80 kV, standard pulse wave
Bandwidth DC to 50 MHz, within -3 dB
Rise time 7 ns or less (for probes only)
Input RC 1000 MW ±5% //5 pF ±2 pF
Attenuation 2000:1 ±5%
Cable length Approx. 4 m
Connector BNC type
Used for Oscilloscope with input RC: 1 MW, 15 to 50 pF
Size Approx. 88 mm (ø) x 338 mm (L)
Weight Approx. 3.5 kg (including accessories)
Accessories Matching box, clamp, probe tip, ground lead, adjusting screwdriver, accessory bag
Options High-voltage probe stand SK-301 (produced upon order)
The SK-301 can be used with both the HV-P60 and the HV-P30. It is attached by turning the probe bracket upside down (for HV-P60/HV-P30).

* The P-P voltage drops if the CW is 100 kHz or greater.

This is a passive probe that measures high-voltage waveforms by connecting to an oscilloscope, and has the following characteristics: the bandwidth is DC to 50 MHz, the maximum input is DC 60 kV, and the attenuation is 2000:1.
Characteristic curve
Maximum Input Voltage and Frequency (Sine Wave) [HV-P60]

Maximum Input Voltage and Frequency (Sine Wave) [HV-P60]

HV-P30


HV-P30
High-voltage probe stand SK-301 (sold separately)

High-voltage waveforms of up to DC 30 kV, pulse 40 kV measured by oscilloscope

 

Wide bandwidth, DC to 50 MHz

 

Maintenance-free, due to use of silicon rubber - guarantees stable withstand voltage

Specifications
Maximum input voltage DC 30 kV or DC + AC peak*
Single-shot pulse of 40 kV, repetitive signal
Bandwidth DC to 50 MHz, within -3dB
Rise time 7 ns or less (for probes only)
Input RC 100 MW ±5% //7 pF or less
Attenuation 1000:1 ±5%
Cable length Approx. 3 m
Connector BNC type
Used for Oscilloscope with input RC: 1 MW, 15 to 50 pF
Size Approx. 66 mm (ø) x 315 mm (L)
Weight Approx. 3 kg (including accessories)
Accessories Matching box, clamp, probe tip, ground lead, adjusting screwdriver, accessory bag
Options High-voltage probe stand SK-301 (produced upon order)
The SK-301 can be used with both the HV-P60 and the HV-P30. It is attached by turning the probe bracket upside down (for HV-P60/HV-P30).

* The P-P voltage drops if the CW is 100 kHz or greater.

This is a passive probe that measures high-voltage waveforms by connecting to an oscilloscope, and has the following characteristics: the bandwidth is DC to 50 MHz, the maximum input is DC 30 kV, and the attenuation is 1000:1.
Characteristic curve
Maximum Input Voltage and Frequency (Sine Wave) [HV-P30]

Maximum Input Voltage and Frequency (Sine Wave) [HV-P30]

 