简介:POWERLINK MN and CN Protocol SoftwareSoftware package for the development ofmanaging nodes (MN) and controlled nodes (CN)Highlights Scope of functions based on the current POWERLINK DS 1.1.0specification Operation speedoptimized,modular software structure Allows for simple and rapid development of POWERLINK devices (managing nodes and controlled nodes) Comprehensive configuration and scaling p...
Brand
Made In
Modle PXF0388
Disctount
PassionTech Ord OrderNum Product Name Price RMB Brand  
PXO_02121.02.0291.00000Powerlink Software for CN (Product Line License)74334~82159ixxat
PXO_02131.02.0293.00000Powerlink Software for MN/CN (Product License)149560~165303ixxat
PXO_02141.02.0294.00000Powerlink Software for MN/CN (Product Line License)221166~244447ixxat
PXO_02151.02.0298.20100Redundant Managing Node - Option for Powerlink Software (Product Line License)55980~61873ixxat
PXO_02161.02.0298.20200Link Selector RMII - Option for Powerlink Software (Product Line License)37626~41587ixxat
PXO_02171.02.0298.20201Link Selector MII - Option for Powerlink Software (Product Line License)37626~41587ixxat
PXO_02181.02.0298.20300Multiple Poll Response - Option for Powerlink Software (Product Line License)23861~26372ixxat
PXO_02191.02.0298.20400Ring Redundancy Manager RMII - Option for Powerlink Software (Product Line Licen55980~61873ixxat
PXO_02201.02.0298.20401Ring Redundancy Manager MII - Option for Powerlink Software (Product Line Licens55980~61873ixxat
PXO_02211.02.0340.10000Powerlink FPGA Design (Product License)55980~61873ixxat
PXO_02221.02.0340.20000Powerlink FPGA Design (Product Line License)92688~102445ixxat
PXO_02231.02.0342.00000Powerlink FPGA MN IP Core Design147750~163303ixxat
PXO_03511.02.0341.10001Link Selektor RMII (Product License)44536~49224ixxat
PXO_03521.02.0341.20001Link Selektor RMII (Product Line License)66500~73500ixxat
PXO_03531.02.0341.10002Link Selektor MII (Product License)44536~49224ixxat
PXO_03541.02.0341.20002Link Selektor MII (Product Line License)66500~73500ixxat
PXO_03551.02.0341.10003Ring Redundanz Manager RMII (Product License)44536~49224ixxat
PXO_03561.02.0341.20003Ring Redundanz Manager RMII (Product Line License)66500~73500ixxat
PXO_03571.02.0341.10004Ring Redundanz Manager MII (Product License)44536~49224ixxat
PXO_03581.02.0341.20004Ring Redundanz Manager MII (Product Line License)66500~73500ixxat
PXO_30011.02.0291.00000Powerlink Software for CN (Product Line License)74334~82159ixxat
PXO_30021.02.0293.00000Powerlink Software for MN/CN (Product License)149560~165303ixxat
PXO_30031.02.0294.00000Powerlink Software for MN/CN (Product Line License)221166~244447ixxat
PXO_30041.02.0298.20100Redundant Managing Node - Option for Powerlink Software (Product Line License)55980~61873ixxat
PXO_30051.02.0298.20200Link Selector RMII - Option for Powerlink Software (Product Line License)37626~41587ixxat
PXO_30061.02.0298.20201Link Selector MII - Option for Powerlink Software (Product Line License)37626~41587ixxat
PXO_30071.02.0298.20300Multiple Poll Response - Option for Powerlink Software (Product Line License)23861~26372ixxat
PXO_30081.02.0298.20400Ring Redundancy Manager RMII - Option for Powerlink Software (Product Line Licen55980~61873ixxat
PXO_30091.02.0298.20401Ring Redundancy Manager MII - Option for Powerlink Software (Product Line Licens55980~61873ixxat
PXO_30101.02.0340.10000Powerlink FPGA Design (Product License)55980~61873ixxat
PXO_30111.02.0340.20000Powerlink FPGA Design (Product Line License)92688~102445ixxat
PXO_30121.02.0342.00000Powerlink FPGA MN IP Core Design147750~163303ixxat
PXO_31351.02.0341.10001Link Selektor RMII (Product License)44536~49224ixxat
PXO_31361.02.0341.20001Link Selektor RMII (Product Line License)66500~73500ixxat
PXO_31371.02.0341.10002Link Selektor MII (Product License)44536~49224ixxat
PXO_31381.02.0341.20002Link Selektor MII (Product Line License)66500~73500ixxat
PXO_31391.02.0341.10003Ring Redundanz Manager RMII (Product License)44536~49224ixxat
PXO_31401.02.0341.20003Ring Redundanz Manager RMII (Product Line License)66500~73500ixxat
PXO_31411.02.0341.10004Ring Redundanz Manager MII (Product License)44536~49224ixxat
PXO_31421.02.0341.20004Ring Redundanz Manager MII (Product Line License)66500~73500ixxat
该文章系原厂商文章翻译,不通之处请参考原文

 

POWERLINK MN and CN Protocol Software

Software package for the development of 
managing nodes (MN) and controlled nodes (CN)



Highlights

  • Scope of functions based on the current POWERLINK DS 1.1.0 specification
  • Operation speed optimized, modular software structure
  • Allows for simple and rapid development of POWERLINK devices (managing nodes and controlled nodes)
  • Comprehensive configuration and scaling possibilities
  • Clearly structured programming interface for connection of the application program
  • "C" source code can be used with any target system
  • Capable of operating either with or without operating system
  • Adaptable to various Ethernet controller architectures and hardware architectures (e.g. 1-CPU, 2-CPU) via internal interfaces
  • Dynamic modification of the Object Dictionary during operation
  • Multi-channel capability
  • Configuration manager for automatic network configuration
  • Certified component as used in the Evaluation Kit for the IEM/POWERLINK and other OEM products


ETHERNET Powerlink MN/CN Protocol Software - Module Overview



Overview of functions

The POWERLINK protocol software contains all necessary functions to implement managing (MN) and controlled nodes (CN) in accordance with the POWERLINK specification. A UDP/IP stack that is required to run the SDO protocol via UDP can be supplied as an extra option. Integration of a UDP/IP stack by the user is greatly simplified by the internal interfaces of the POWERLINK protocol software.

Encapsulation of hard real-time tasks and
hardware specific adaptation

The lower layers of the POWERLINK software are specifically designed to guarantee fast response times of real-time events on the POWERLINK bus as well as the efficient processing of the POWERLINK cycle on the MN. Therefore, the access to and the handling of the Ethernet controller is encapsulated within a separate module, the lower layer driver (LLD). For an adaptation of the POWERLINK software to a specific CPU or hardware platform, this module needs to be modified. This abstraction between hardware-dependant routines and the higher layers of the POWERLINK software makes it possible to provide a high degree of scalability and adaptability. A configuration tool delivered with the software allows optimum adaptation of the POWERLINK functionality provided by the protocol stack to the given application which guarantees an extremely resource-efficient implementation. Compared with the CN version, the MN/CN version allows to switch the MN/CN functions during runtime. MN specific functions and objects are not available in the CN only version which saves system resoures.

Object dictionary and programming interface
The object dictionary is the interface between application and communication. Each object dictionary entry can be directly allocated a reference to a variable with application data. PDOs and SDOs access these application variables directly. Therefore, no modifications to an existing CANopen application are necessary to integrate the POWERLINK protocol software for example.
User-specific call-back functions can be linked to every application object and enable an event-controlled notification of the application in the event of accesses to these objects. This mechanism allows a direct, application-specific reaction on modifications to the application data caused on the bus side. In addition, saving and recovery of configured data is also supported. The application is also able to build or modify parts of the Object Dictionary during operation.

Process (PDO) and Service Data Objects (SDO)
The POWERLINK protocol software supports both dynamic and static PDO-mapping and allows a true producer / consumer communication.
In addition to PDO communication, the SDO protocol necessary for configuration and diagnostics is also implemented in the POWERLINK protocol software. It allows safe transmission of non-real-time-critical data. The SDO protocol can be run via UDP/IP or via ASend (POWERLINK frames).

Multi-channel support
The POWERLINK protocol software enables the implementation of several independent POWERLINK interfaces in one device. Managing node or controlled nodes can be configured independently as well as with independent object dictionaries in each case. In this way, gateways can be developed that are connected to a higher order POWERLINK network with one POWERLINK channel as a CN and control a POWERLINK sub-network as a MN with the second POWERLINK channel.

Network management
One important task of the MN is network management, which includes start-up and monitoring of the network nodes. The MN capable version of the protocol software supports the complete boot-up procedure for mandatory and optional CNs as defined in the POWERLINK DS 1.1.0 specification.
Software updates of CNs by the managing node are also supported.
The POWERLINK protocol software includes the configuration manager which allows for device configurations to be checked and updated during the boot-up process. With the aid of the configuration manager it is easy to replace defective devices while a network is in operation without interaction of the application. In this case no manual configuration of the replacement device is required before installation by the service technician.

Redundant MN
Optionally redundant MNs according to EPSG WDP 302-A V 1.0.4 can be implemented based on the POWERLINK MN/CN protocol software. Redundant MNs are typically used in applications where a high availability of the systems is required. If the active MN fails, the next redundant MN takes the role of the active MN and provides seamless communication among all POWERLINK nodes.

Operating system support
The POWERLINK stack can be used with or without an operating system. The software has an internal scheduler which insures the optimal allocation of the available process time resources. By using an operating system, the POWERLINK stack is executed as one task. Only basic operating system functions like semaphores and tasks are required. These functions are encapsulated by an abstraction layer (GOE - Generic Operating Environment) and can be easily adapted to the operating system.

Reference platform
The provided "C" source code can be used on any target system. Besides the generic version, the delivered software package includes a reference implementation, which work on Freescale Coldfire 523x and Altera NIOS II based systems without the need of additional adaptation. Evaluation boards with wiring diagrams (reference schematics) are also available.


Contents of delivery

 

  • "C" source code
  • Reference implementation for Coldfire 523x and NIOS II
  • Software license
  • Manual
  • Technical support

Supplementary Services

  • Service Contract
    In addition to the software package IXXAT offers a software service contract. During the term of the contract, IXXAT provides the following services:
    - Free updates and bug fixing
    - Technical support via telephone including answering
    questions regarding general POWERLINK issues.
     
  • Code Introduction
    IXXAT offers comprehensive one- or two-day detailed introductions to the code. Interfaces, sequences and data flows within the POWERLINK software are explained. Questions are also answered concerning the adaptation to be carried out, and adaptations to the code can be made.
     
  • Technical support
    Support in the specification of the POWERLINK device or system to be implemented. Here the customer benefits from our comprehensive POWERLINK applied expertise, allowing errors to be avoided and better solutions to be developed within a shorter period of time.
     
  • Implementation support
    IXXAT handles adaptation, implementation and testing of the Powerlink protocol software for your hardware or application.
     
  • Seminars
    IXXAT offers a seminar on POWERLINK. The seminar can also be held in-house on request.
Related Products
Question About the Products  If you have Anyquestion about the products,Please write here!
Title:
Input Question:
Contact:
 

 

请您留言

感谢您的关注,当前客服人员不在线,请填写一下您的信息,我们会尽快和您联系。

提交