网关 for the integration of CANopen networks in POWERLINK systems
Product status | Product announcement (this product is at the moment under development, dates on request) |
With the POWERLINK Version V2, many CANopen communication mechanisms which have already proven to be very useful in CAN systems have been adopted for Ethernet. POWERLINK thus combines short cycle times and the high bandwidth of the Ethernet with the proven CANopen mechanisms such as the object model or process and service data communication. Finally, the POWERLINK can be regarded as a further development of the CANopen, to accommodate the increasing requirements of transmission bandwidth and network extension of today's applications.
Because of the great similarity between CANopen and POWERLINK, an extension or integration of CANopen systems with POWERLINK is achievable. Existing CANopen systems can be extended by POWERLINK in many ways with the aid of special POWERLINK/CANopen-网关s. In this way, for example, several CANopen segments can also be linked with each 其他 over large distances. In addition, central data logging can be carried out over several CANopen sub-segments due to the high bandwidth of the POWERLINK network.
With the aid of the POWERLINK/CANopen-网关, it is also possible to ex改变 service data between POWERLINK and CANopen networks in addition to the ex改变 of process data.
The IXXAT POWERLINK/CANopen-网关 offers a simple way of combining CANopen and POWERLINK networks. From the point of view of the POWERLINK network, the gateway provides access to the input and output data of the CANopen network. With the aid of the configuration of the gateway, the process data that shall be ex改变d between the CANopen and the POWERLINK network can be defined.
Picture: Coupling of POWERLINK and CANopen segments
On the CANopen side, the POWERLINK/CANopen-网关 can be configured either as a master or as a slave. Synchronization of the CANopen network by the very precise POWERLINK SoC message is also possible. If the gateway is configured as a CANopen NMT master, start-up of the CANopen network can be synchronized with the POWERLINK network. It is also possible to route CANopen emergency messages into the POWERLINK network to allow for error monitoring of the CANopen network via POWERLINK.
Technical specifications/Features
- POWERLINK controlled node in accordance with POWERLINK Version V2
- CANopen master/slave function
- RJ45 Ethernet 连接or
- CANopen-compliant Sub-D 连接or
- POWERLINK node ID adjustable via software
- Display of the CANopen and POWERLINK network status via separate LEDs
- Plastic housing for hat rail assembly
Areas of application
- Extension of the topology of the CANopen systems with POWERLINK as a backbone network
- Integration of already automated CANopen sub-systems in higher order POWERLINK network
- Central logging of large quantities of process data via POWERLINK from CANopen sub-networks
Content of delivery
- POWERLINK/CANopen-网关
- Configuration software to set Powerlink node ID
- Manual
Further information
The technical details and features of the POWERLINK/CANopen-网关 may 改变. Up-to-date information on our POWERLINK products is available on our website.
Order number
On request | POWERLINK/CANopen-网关 |