POWERLINK Configuration Framework

关键词: POWERLINK,Configuration,Framework

简介:POWERLINK Configuration FrameworkComponent for integration of a projecting and configurationfunction for POWERLINK systems in OEM tools Product status Product announcement (this product is at the moment under development, dates on request) OverviewThe POWERLINK Configuration Framework allows for the integration ofprojecting and configurationfunctionality into OEM tools such as...
品 牌 ixxat ixxat
产 地 德国
型 号 PXF0700
折 扣 3个以上折扣12%
10个以上折扣15%
25个以上折扣20%
50个以上折扣25%
100个以上折扣30%
200个以上折扣33%
500个以上折扣38%
1000个以上折扣40%
其他电询
咨询专家:

黄工-工业总线-工业自动化-实时仿真

黄工-工业总线-工业自动化-实时仿真 ID:2937

   机电电子工程专业硕士,机械设计制造及其自动化/计算机双学士,高级工程师

    具有丰富的从业、管理经验,曾在机电工程公司,资深设计代理公司工作。历任组织、经理等岗位,同时具有深厚的理论基础和项目项目研发经历。...

[MORE]

赵工-总线系统-嵌入式系统-工业自动化

赵工-总线系统-嵌入式系统-工业自动化 ID:2940

    机械电子工程,嵌入式系统专家,高级工程师

    嵌入式项目开发,ARM,Freescale,Infilion等系列单片机系统开发,DSP嵌入式系统开发,FPGA系统开发,项目经验丰富。


...

[MORE]

产品说明:

 

POWERLINK Configuration Framework

Component for integration of a projecting and configuration 
function for POWERLINK systems in OEM tools



Product status Product announcement (this product is at the moment under development, dates on request)


Overview

The POWERLINK Configuration Framework allows for the integration of projecting and configuration functionality into OEM tools such as PLC programming environments while maintaining a uniform look and feel.

The framework provides all the necessary components and mechanisms required for creation and management of configuration data of a POWERLINK project. The framework itself is delivered without user interface, which has to be provided by the OEM tool. This offers the following advantages: all system data is centrally accessible in the interface and can be centrally edited, the OEM tool has a uniform look and feel, and POWERLINK-relevant configuration data can be displayed to the user at system level in abstracted form.


 

Powerlink Configuration Framework - Module Overview



Highlights
  • Automatic PDO-mapping and PDO-linking
  • Automatic calculation and configuration of the POWERLINK network timing parameters
  • Support of network variables in accordance with CiA DS302/DS405
  • Clear and simple access to the device data
  • Fast, database-based management of all configuration and device data from device description files
  • Management of any number of device description files in one catalogue
  • COM-based interface for integration in OEM tools


描述 of functions

Catalog
A catalog system enables device description files to be imported and stored in a database. This is useful if POWERLINK devices are used repeatedly in projects as they can then be selected directly in the catalog and added to a project. It is also possible for an OEM to define which POWERLINK devices the customer may use in OEM systems, preventing the customer from using unauthorized devices.

Automatic PDO-mapping and PDO-linking
For larger systems, the specialized applied expertise required for PDO-mapping/linking and the time-consuming, careful selection of the individual PDO links requires great effort. The POWERLINK Configuration Framework supports the creation of PDO mappings and the correct allocation of the PDOs to the devices (PDO linking) by means of an automated system. This allows to create I/O links without detailed knowledge of POWERLINK.

Network variables in accordance with CANopen CiA 302/405
An其他 function provided by the POWERLINK Configuration Framework is the definition and management of network variables in accordance with the specifications DS302 or DS405 of CAN-in-Automation. Network variables are typically used by PLCs because of the possibility to link the data (variables) of the application program with data of 其他 devices. Based on these links, the Configuration Framework can then automatically calculate the PDO mapping and linking.

Automatic calculation of the POWERLINK communication cycle
Depending on the timing data of the individual POWERLINK devices and the lengths of the individual PDOs, the calculation of the POWERLINK communication cycle and the configuration values for the timing parameters of both the managing node and the controlled 节点 is performed. This function is automatically carried out by the POWERLINK Configuration Framework.

Import / export of device description files (EDS/DCF)
A powerful import and export of device description files enables importing and exporting of devices to and from the catalogue as well as the exporting of configuration data of individual devices from a project.

Generation of configuration data files
After completion of projecting or configuration of a POWERLINK system, the POWERLINK Configuration Framework creates a configuration data file. This configuration data file is then normally sent to the managing node. The configuration data file is created in the Concise DCF format.

Programming interface
The programming interface of the POWERLINK Configuration Framework is implemented as a COM interface. It provides various interfaces for the management of the catalogue, of the projects and of the individual devices in a project. This enables simple integration of the POWERLINK Configuration Framework in OEM tools.

System requirements
- Windows 2000 with SP4 or Windows XP with SP2


Order number

On request POWERLINK Configuration Framework
参数资料:
POWERLINK Configuration FrameworkPOWERLINK,Configuration,Framework
该文章系原厂商文章翻译,不通之处请参考原文
价格列表: POWERLINK Configuration FrameworkPOWERLINK,Configuration,Framework
葩星订货号 订货号 产品名称 报价 品牌  
相关产品: POWERLINK Configuration FrameworkPOWERLINK,Configuration,Framework

  咨询历史: